TM 5-3820-246-14&P
4-18. AIR CLEANER
Cleaning/Inspection.
c.
(1) Wipe debris off cover (3). Inspect for cracks
or other damage.
(2) Clean air cleaner element (4) (para 2-12).
(3) Inspect all parts for wear, obstructions, or
other damage. Replace damaged parts.
Wipe off air fitting (5) and suction pipe (6)
(4)
with a dry rag.
Assembly.
d.
(1) Install suction pipe (6) and air fitting (5) on
element case (3).
(2) Install air cleaner element (4) in element
case (3).
(3) Install element case (3).
NOTE
Insure that the suction pipe and air fitting
are fully seated in the air cleaner element
case.
Installation.
e.
(1) Install air cleaner cover (2) by pushing down firmly on mounting studs.
(2) Install three nuts (1). Tighten 36 lb-in (4.1 N-m).
END OF TASK