LO 5-3895-373-12
Note 22
ON-CONDITION or ANNUAL or 2250 HOURS
HYDRAULIC OIL CHANGE
A
Open center top right access door, right access
door and remove right access cover per TM 5-
3895-373-10.
WARNING
Hydraulic oil can be moderately
flammable and can be an irritant to
the skin, eyes, and respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
B
Remove drain plug (1) from drain hose (2).
Drain hydraulic oil into suitable container.
Dispose of hydraulic oil in accordance with local
procedures.
WARNING
Cleaning solvent, P-D-680, Type ill, is
TOXIC and flammable.
Wear
protective goggles and gloves. Use
only in a well ventilated area. Avoid
contact with skin, eyes, and clothes,
and do not breathe vapors. Keep
away from heat or flame.
Never
smoke when using solvent; the
flashpoint for Type III cleaning
solvent is 200F (93,3C). Failure to
do so may result in injury or death to
personnel.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact.
Wear safety
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
C
Clean drain plug (1) with cleaning cloth and
cleaning solvent. Apply hydraulic fitting sealant
to the threads of drain plug and install into drain
hose (2).
Card 26 of 28