LO 5-3895-373-12
Note 18 (Continued)
ANNUAL or 1000 HOURS
WARNING
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact.
Wear safety
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
K
Apply hydraulic fitting sealant
to
exposed
threads of straight adapter (3).
CAUTION
Be careful not to overtighten tube
fitting (4) on straight adapter (3).
Overtightening will cause stripping of
brass screw threads or shearing of
adapter.
L
Install and tighten tube fitting (4 ) on straight
adapter (3). Use backup wrench across adapter
flats and do not overtighten tube fitting.
M
Remove cribbing per TM 5-3895-373-10.
Card 20 of 28