TM 5-3820-246-14&P
c. Flooded Machine. Check exhaust outlet for
liquid. If it is wet:
(1) Turn fuel knob (1) CW to the stop (off).
Personnel hearing can be
PERMANENTLY DAMAGED if exposed
to constant high noise levels of 85 dB (A)
or greater. Wear approved hearing
protection devices when working in high
noise level areas. Personnel exposed to
high noise levels shall participate in a
hearing conservation program in
accordance with TB MED 501. Hearing
loss occurs gradually but becomes
permanent over time.
(2) Pull starter cord (2) until machine runs,
allow to run until all excess fuel is burnt and
engine stops.
(3) Turn fuel knob (1) CCW approximately l/2
turn.
(4) Pull starter cord (2) immediately and make
any final adjustments to bring the operating
speed to its maximum.
2-9