TM 5-3820-246-14&P
To shut down, turn fuel knob (1) fully CW, close fuel
valve (2) and close fuel tank cap vent (3).
2-12. AIR CLEANER ELEMENT CLEANING.
handled and disposed of only by authorized
and trained personnel. The unit
commander or senior officer in charge of
maintenance personnel must ensure that
prescribed protective clothing (FM 3-4) is
used, and prescribed safety measures and
decontamination procedures (FM 3-5) are
followed. The local unit SOP is
responsible for final disposal of
contaminated air filters. Failure to comply
may cause severe injury or death to
personnel.
a.
Removal.
(1) Remove three nuts (1) using 10 mm wrench
and cover (2).
(2) Slide filter element (3) from element
case (4).