TM 5-3895-376-14&P
Section VII. PREPARATION FOR STORAGE OR SHIPMENT
4-41. GENERAL
This section provides instructions for preparing the
compactor for short term and intermediate storage or
shipment.
4-42. ADMINISTRATIVE STORAGE
Administrative storage shall be in accordance with AR
750-1.
4-43. SHORT TERM STORAGE (30 days or less)
W A R N I N G
Do not smoke or use an open flame in
the vicinity when filling fuel tank. Fire
and/or explosion may result in damage
to compactor and injury to personnel.
a.
Fill the fuel tank with W-F-800 diesel fuel.
W A R N I N G
Carbon monoxide occurs in the ex-
haust fumes of internal combustion en-
gines and becomes dangerously
concentrated under conditions of inade-
quate ventilation. Observe the following
safety precautions whenever the engine
is running:
Operate engine in a ventilated area
only.
Do not idle the engine for long peri-
ods without maintaining adequate
ventilation.
Be alert at all times for exhaust
odors and exposure symptoms.
Be aware: the field protective mask
for chemical biological radiological
(CBR) protection will not protect you
from carbon monoxide poisoning.
b.
Start the engine (Para. 2-5) and operate the com-
pactor for 2 minutes at full load speed.
c.
Shutdown the engine (Para. 2-7).
NOTE
Do not drain the fuel system after this run.
d.
Check oil level in engine and fill to maximum
mark on dipstick.
e.
Service the pre-cleaner (Para. 3-6).
f.
Stow the compactor on level surface in an area
protected from the elements.
4-44. INTERMEDIATE TERM STORAGE (more
than 30 days)
a.
b.
C.
d.
W A R N I N G
Carbon monoxide occurs in the ex-
haust fumes of internal combustion en-
gines and becomes dangerously
concentrated under conditions of inade-
quate ventilation. Observe the following
safety precautions whenever the engine
is running:
Operate engine in a ventilated area
only.
Do not idle the engine for long peri-
ods without maintaining adequate
ventilation.
Be alert at all times for exhaust
odors and exposure symptoms.
Be aware: the field protective mask
for chemical biological radiological
(CBR) protection will not protect you
from carbon monoxide poisoning.
Start the engine (Para. 2-5) and operate the com-
pactor for 10 minutes at full load speed to bring
engine to normal operating temperature.
Shutdown the engine (Para. 2-7).
Drain the engine oil (Para. 4-12), and fill crank-
case to proper level with preservative lubricating
oil (MIL-L-2160, Grade 2, or equivalent).
Drain the fuel tank (Para. 4-30), and refill tank
with 1 pint (0.5 liter) mixture of 9 parts W-F-800
diesel fuel and 1 part preservative lubricating oil
(MIL-L-2160, Grade 2, or equivalent).
4-74